ustransplant.org

Transplant Statistics: Annual Report : Reference Tables


Annual Report | Chapters | Data By Category | Data By Organ | Technical Notes | Glossary | Appendices

Table 5.8a
Graft Survival and Standard Errors at 3 Months, 1 Year, 3 Years, and 5 Years
Deceased Donor Kidney Transplants

  3 Months 1 Year 3 Years 5 Years
N % Std. Err. N % Std. Err. N % Std. Err. N % Std. Err.
Total All 15,850 93.5% 0.2% 15,850 88.4% 0.3% 15,510 78.5% 0.3% 15,186 63.3% 0.4%
Level of HLA Mismatch 0 2,667 94.3% 0.5% 2,667 90.4% 0.6% 2,410 83.2% 0.8% 2,322 70.2% 1.0%
1 481 95.4% 1.0% 481 91.4% 1.3% 539 82.3% 1.7% 560 63.6% 2.2%
2 1,649 95.1% 0.5% 1,649 90.4% 0.7% 1,797 81.1% 1.0% 1,944 63.9% 1.2%
3 3,285 94.2% 0.4% 3,285 89.2% 0.6% 3,482 79.3% 0.7% 3,484 63.2% 0.9%
4 3,506 93.0% 0.4% 3,506 87.5% 0.6% 3,549 76.6% 0.7% 3,624 61.9% 0.9%
5 2,860 92.0% 0.5% 2,860 86.4% 0.7% 2,510 75.3% 0.9% 2,232 60.3% 1.1%
6 1,376 92.2% 0.7% 1,376 85.6% 1.0% 1,193 73.5% 1.3% 1,006 58.4% 1.7%
Unknown 26 92.3% 5.2% 26 84.2% 7.2% 30 86.5% 6.3% 14 78.6% 11.0%

Source: OPTN/SRTR Data as of August 1, 2002.
(+) = Values not determined due to insufficient follow-up.
(-) = Values not determined since there were no transplants in the category.
Cohorts are transplants performed during 1999-2000 for 3 month and 1 year; 1997-1998 for 3 year; and 1995-1996
for 5 year survival.
Graft survival follows individual transplants until graft failure. Counts for patient and graft survival are different because a patient may have more than one transplant for
a type of organ.
Center volume = Center's yearly transplants performed during the base period, based on kidney and kidney-pancreas
transplants.
Multi-organ transplants are excluded.


Annual Report | Chapters | Data By Category | Data By Organ | Technical Notes | Glossary | Appendices

Center-Specific Reports | OPO Reports | National Reports | Data Accuracy | Report Timeline

Home | Who We Are | What We Do | About Transplants | Transplant Statistics | Research Resources | Contact Us | Site Map

SRTR Site designed and maintained by Diamond Bullet Design & URREA.